Model |
UP-6118-A |
UP-6118- |
UP-6118-C |
UP-6118-D |
UP-6118-E |
UP-6118-F |
|
Inner size: WHD(cm) |
40*35*30 |
50*30*40 |
50*40*40 |
50*50*40 |
60*40*50 |
60*50*50 |
|
External size: WHD(cm) |
150*180*150 |
160*175*160 |
160*185*160 |
160*185*170 |
170*185*170 |
170*195*170 |
| Temperature range(Test Chamber) | high temperature:+60ºC~+200ºC;low temperature -10ºC~-65ºC(A:-45ºC;B:-55ºC;C:-65ºC) | |||||
| Heating Time | RT~200ºC About 30min | |||||
| Cooling Time | RT~-70ºC About 85min | |||||
| Temperature Conversion Time | Less than 10S | |||||
| Temperature Recovery Time | Less than 5min | |||||
| Temperature Deviation | ±2.0ºC | |||||
| Temperature Fluctuation | ±0.5ºC | |||||
| Material | External material: SUS#304 Stainless steel plate Internal material:SUS#304Stainless steel plate |
|||||
| Output Mode | Water-cooled or air-cooled,Taikang compressor in France | |||||
| Controller | TEMI South Korea | |||||
| Cooling System | Water-cooled or air-cooled | |||||
| Protection devices | Fuse switch, compressor overload switch, refrigerant high and low pressure protection switch,super humidity over-temperature protection switch,fuse, failure warning system | |||||
| patrs | Watching window;50mm testing hole; partition plat | |||||
| Power | AC380V 50/60Hz Three-phase four-wire ac power | |||||
| weight (kg) | 750 | 790 | 830 | 880 | 950 | 1050 |
| 1. Profile. | |
| 1.1 Item | Thermal shock test chamber (three zone) |
| 1.2 Model | UP-6118 |
| 1.3 Sample restrictions | The equipment is prohibited to do the test and storing as below: - Flammable, explosive, volastile substances; - Corrosive substances; - Biological samples; - Source of strong electromagnetic radiation. |
| 1.4 Test condition | Envrionmental temperature: +25ºC; humidity: ≤85%, with no samples inside the chamber |
| 1.5 Test method | GB/T 5170.2-1996 temperature test chamber and so on |
| 1.6 Meet the test standard | Meet GB2423, IEC68-2-14, JIS C 0025, MIL-STD-883E, IPC 2.6.7, BELLCORE and other standards |
| 2. Technical parameters. | |
| Inner size (WxHxD)mm | 400×350×300mm |
| Inner volume | 42L |
| External size (WxHxD)mm | 1550x1650x 1470mm |
| Preheating temperature | +60ºC~+200ºC (heat up +25ºC~+200ºC/20min) |
| Precooling temperature | -10ºC ~-45ºC (cooling +25ºC~-45 ºC/65min) |
| High temp. shock range | +60ºC~+150ºC |
| Low temp. shock range | -10ºC~-40ºC |
| Temperature fluctuation | ±0.5ºC |
| Temperature deviation | ±2.0ºC |
| Shock recovery time | ≤5min (control point) |
| 3. Structure | |
| 3-1. Inner & External chamber material | Inner / External chamber: stainless steel plate (SUS # 304) |
| 3-2. Main structure design | Divided into low temperature storing area, product testing area, high temperature heat storing area. |
| 3-3. Cooling storage / heating storage material | High efficiency aluminum enable heat storage capacity and super-cold capacity to reach super fast exchanging. |
| 3-4.Environmental conditions | Meet MIL , IEC , JIS ,IPC etc. and the specifications of the chamber |
| 3-6. Testing hole | For connecting external testing wire and signal (10.0cm) of 1 piece |
| 3-7. Table running wheel | Moving position adjustbale and forced fixed knot position (500kg/wheel) |
| 3-8. Thermal insulating layer | Burning fire resistant thermal insulation layer PU + thermal insulation wool (thermal insulation thickness of 12.0 cm) |
| 3-9. Frame inside chamber | Height adjustable grid shelves and stainless steel mesh grid plate (2pcs, separation distance of 5.0cm ) |
| 4. Supply air circulation system | |
| 4-1.Electric heating circulatory system | utilize circulatory motor of special moisture-proof, with stainless steel extension axis. |
| 4-2. Circulating fan | High/low temperature resistance aluminum alloy multi-wing centrifugal wind wheel. |
| 4-3. High evenness air flue | Positive pressure outlet design to achieve high uniformity requirements. |
| 4-4. Temp. electric heating control | Balanced temp. P.I.D + P.W.M + S.S.R system. |
| 4-5. Microcomputer control | Microcomputer control, pre-cooling zone, preheating zone and temperature conversion in the test zone, output power which is calculated by computer to achieve high accuracy and high efficiency electricity. |
| 5. Refrigeration system | |
| 5-1. Refrigeration device | |
| 5-2. Hot and cold switching device | Taiwan (Kaori) ultra-efficient 316# stainless steel plate cold & heat refrigerant exchanging design. |
| 5-3. Heating load regulation | Adjust the flow of refrigerant by microcomputer automatically which takes heat load effectively for the samples waiting to be tested; compared to the traditional design, it improves control stability and reproducibility, also achieves power saving to get super efficiency. |
| 5-4. Condenser | |
| 5-5.Effeciency super freezing control refrigerant | Refrigerant pipes are welded with pressurized nitrogen and passed leak test. |
| 5-6. Evaporator | Slope evaporator with high efficiency component (AC & R double spoiler aluminum fins). |
| 5-7. Standard modular | Compatibility and interoperability of components of high quality and stability. |
| 5-8.Expansion of performance | The control system can reserve isothermal control Liquid nitrogen valve LN2V and refrigerant valve FV control interface. |
| 6. Control system | |
| 6-1 Controller | |
| A. Temperature sensor | T-type rapid induction sensor. |
| B. Temperature converter | Automatic correction of linear compensation temperature converter by microcomputer |
Our service:
During the whole business process, we offer Consultative Selling service.