Designed for reliability testing of automotive electronics, new‑energy battery components, semiconductor chips, PCBs, optoelectronic devices, communication modules, aerospace parts and household appliances. It serves R&D validation, production screening and batch quality inspection within the electronics and electrical industries.
| Item | Specification |
| Temperature Range | -70℃ ~ +150℃ (Optional) |
| Linear Temp. Change Rate | 1℃-15℃/min (Linear continuous ramp, customizable) |
| Temperature Uniformity | ≤±1.0℃ |
| Temperature Fluctuation | ≤±0.5℃ |
| Refrigeration System | Air-cooled / Water-cooled cascade refrigeration |
| Control System | PLC + Touch-screen controller, programmable rampsoak function |
| Safety Protection | Over-temp protection, overload protection, low-pressure alarm, power-failure recovery function |
| Power Supply | AC380V±10% 50Hz 3-phase / Customized |
Q1: What is the difference between a linear rapid temperature change chamber and a regular temperature cycling chamber?
A: A linear rapid temperature change chamber provides continuous linear temperature ramping without step‑wise pauses to meet strict linear‑rate requirements. Conventional temperature‑cycling chambers typically use stepped temperature transitions.
Q2: Can I customize the temperature range and temperature‑change rate?
A: Yes. Temperature range, linear ramp rate and inner chamber dimensions can all be customized according to your test specifications.
Q3: Should I choose air‑cooled or water‑cooled refrigeration?
A: Air‑cooled units feature simple installation with no extra cooling tower required. Water‑cooled units deliver more stable performance during prolonged high‑load operation.
Q4: Does this chamber meet MIL‑STD‑810H test requirements?
A: Yes. The UP‑6195 performs temperature‑cycling tests compliant with MIL‑STD‑810H, alongside relevant IEC and GB/T environmental‑test standards.
Q5: What safety features does this chamber include?
A: It is equipped with over‑temperature protection, overload protection, low‑pressure alarm and power‑failure recovery to protect both equipment and test samples.
Q6: What samples and industries is this chamber suitable for?
A: It is mainly used for reliability and stress‑screening tests on automotive‑electronic parts, new‑energy battery components, semiconductors, PCBs, optoelectronic devices, aerospace components and household appliances.